Olex-Flexs PVC Earth 0.6/1kV 300mm2 Green/Yellow

Description

Description

Standards

  • National
    AS/NZS 1125; AS/NZS 5000.1

One core flexible multiple stranded plain annealed copper, 0.6/1 kV, V-90 PVC, insulated flexible earth cable.

 

For use with flexible Versolex and other PVC single core cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Green / yellow
Conductor flexibility
Class 5
Conductor material
Copper
Conductor shape
Circular
Insulation
V-90
Type of conductor
Stranded flexible
With Green/Yellow core
Yes

Dimensional characteristics

Dimensional characteristics

Approximate weight
275.0 kg/100m
Cable length
1 m
Conductor cross-section
300 mm²
Nominal insulation thickness
2.4 mm
Nominal overall diameter
28.3 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Conductor AC resistance at 50 Hz
0.082 Ohm/km
Insulation resistance at 20°C
3.2 MOhm.km
Max. DC resistance of the conductor at 20°C
0.0641 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible
Maximum Pulling Tension
6 kN

Usage characteristics

Usage characteristics

Minimum Bend Radius - During Installation (under Tension)
255 mm
Minimum Bend Radius - Installed
170 mm

Resources

Resources

PVC Insulated - Current carrying capacity table three phase (in Amps)

Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰C
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu
300.0 620.0 529.0 492.0 388.0 311.0 0.0 434.0 488.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Thermal insulation, partially surrounded by thermal insulation
Thermal Insulation, completely surrounded by thermal insulation
Underground ducts A - Undergound Wiring Enclosure
Underground ducts B - Individual Wiring Enclosure

PVC Insulated - Current carrying capacity table single phase (in Amps)

Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰C
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu
300.0 636.0 582.0 495.0 0.0 0.0 0.0 496.0 546.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Thermal insulation, partially surrounded by thermal insulation
Thermal Insulation, completely surrounded by thermal insulation
Underground ducts A - Undergound Wiring Enclosure
Underground ducts B - Individual Wiring Enclosure

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close