Olex-Flexs Flexible PVC Earth

Products

Olex-Flexs PVC Earth 0.6/1kV 10mm2 Green/Yellow NEW

Nexans ref. BAAX01AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 10 mm²
  • Maximum Pulling Tension: 0.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 38 mm
  • Minimum Bend Radius - Installed: 19 mm

 

Olex-Flexs PVC Earth 0.6/1kV 16mm2 Green/Yellow NEW

Nexans ref. BAAX02AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Maximum Pulling Tension: 0.32 kN
  • Minimum Bend Radius - During Installation (under Tension): 44 mm
  • Minimum Bend Radius - Installed: 22 mm

 

Olex-Flexs PVC Earth 0.6/1kV 25mm2 Green/Yellow NEW

Nexans ref. BAAX03AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Maximum Pulling Tension: 0.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 54 mm
  • Minimum Bend Radius - Installed: 27 mm

 

Olex-Flexs PVC Earth 0.6/1kV 35mm2 Green/Yellow NEW

Nexans ref. BAAX04AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Maximum Pulling Tension: 0.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 61 mm
  • Minimum Bend Radius - Installed: 31 mm

 

Olex-Flexs PVC Earth 0.6/1kV 50mm2 Green/Yellow NEW

Nexans ref. BAAX05AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Maximum Pulling Tension: 1 kN
  • Minimum Bend Radius - During Installation (under Tension): 73 mm
  • Minimum Bend Radius - Installed: 49 mm

 

Olex-Flexs PVC Earth 0.6/1kV 70mm2 Green/Yellow

Nexans ref. BAAX63AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 83 mm
  • Minimum Bend Radius - Installed: 56 mm

 

Olex-Flexs PVC Earth 0.6/1kV 95mm2 Green/Yellow

Nexans ref. BAAX64AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Maximum Pulling Tension: 1.9 kN
  • Minimum Bend Radius - During Installation (under Tension): 96 mm
  • Minimum Bend Radius - Installed: 64 mm

 

Olex-Flexs PVC Earth 0.6/1kV 120mm2 Green/Yellow NEW

Nexans ref. BAAE87AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Maximum Pulling Tension: 2.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 109 mm
  • Minimum Bend Radius - Installed: 73 mm

 

Olex-Flexs PVC Earth 0.6/1kV 150mm2 Green/Yellow NEW

Nexans ref. BAAE88AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Maximum Pulling Tension: 3 kN
  • Minimum Bend Radius - During Installation (under Tension): 121 mm
  • Minimum Bend Radius - Installed: 80 mm

 

Olex-Flexs PVC Earth 0.6/1kV 185mm2 Green/Yellow

Nexans ref. BAAE89AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Maximum Pulling Tension: 3.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 134 mm
  • Minimum Bend Radius - Installed: 90 mm

 

Olex-Flexs PVC Earth 0.6/1kV 240mm2 Green/Yellow

Nexans ref. BAAE90AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Maximum Pulling Tension: 4.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 229 mm
  • Minimum Bend Radius - Installed: 152 mm

 

Olex-Flexs PVC Earth 0.6/1kV 300mm2 Green/Yellow

Nexans ref. BAAE91AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Maximum Pulling Tension: 6 kN
  • Minimum Bend Radius - During Installation (under Tension): 255 mm
  • Minimum Bend Radius - Installed: 170 mm

 

Olex-Flexs PVC Earth 0.6/1kV 400mm2 Green/Yellow

Nexans ref. BAAE92AA001AAHT

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Maximum Pulling Tension: 8 kN
  • Minimum Bend Radius - During Installation (under Tension): 288 mm
  • Minimum Bend Radius - Installed: 192 mm

 

Description

Description

Standards

  • National
    AS/NZS 1125; AS/NZS 5000.1

One core flexible multiple stranded plain annealed copper, 0.6/1 kV, V-90 PVC, insulated flexible earth cable.

 

For use with flexible Versolex and other PVC single core cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Green / yellow
Conductor flexibility
Class 5
Conductor material
Copper
Conductor shape
Circular
Insulation
V-90
Type of conductor
Stranded flexible

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible

Resources

Resources

PVC Insulated - Current carrying capacity table three phase (in Amps)

Copper Conductor

Insulation PVC

Maximum Conductor Temperature 75⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu
1.0 16.0 14.0 13.0 12.0 10.0 6.0 16.0 19.0
1.5 20.0 17.0 16.0 15.0 12.0 8.0 20.0 24.0
2.5 29.0 25.0 23.0 21.0 17.0 12.0 27.0 33.0
4.0 38.0 33.0 31.0 28.0 23.0 16.0 36.0 43.0
6.0 49.0 42.0 40.0 35.0 28.0 20.0 45.0 53.0
10.0 67.0 58.0 54.0 47.0 37.0 27.0 59.0 70.0
16.0 89.0 77.0 72.0 62.0 50.0 36.0 78.0 90.0
25.0 120.0 103.0 97.0 81.0 64.0 48.0 100.0 117.0
35.0 148.0 127.0 119.0 100.0 80.0 59.0 122.0 140.0
50.0 181.0 156.0 146.0 119.0 95.0 0.0 144.0 168.0
70.0 230.0 197.0 184.0 152.0 122.0 0.0 180.0 205.0
95.0 287.0 246.0 230.0 183.0 147.0 0.0 217.0 250.0
120.0 335.0 287.0 267.0 217.0 173.0 0.0 252.0 283.0
150.0 385.0 330.0 308.0 244.0 195.0 0.0 283.0 317.0
185.0 447.0 383.0 357.0 284.0 227.0 0.0 325.0 365.0
240.0 535.0 457.0 426.0 331.0 265.0 0.0 377.0 422.0
300.0 620.0 529.0 492.0 388.0 311.0 0.0 434.0 488.0
400.0 726.0 615.0 573.0 442.0 353.0 0.0 492.0 553.0
500.0 846.0 710.0 661.0 523.0 418.0 0.0 571.0 641.0
630.0 990.0 817.0 760.0 588.0 471.0 0.0 639.0 723.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Thermal insulation, partially surrounded by thermal insulation
Thermal Insulation, completely surrounded by thermal insulation
Underground ducts A - Undergound Wiring Enclosure
Underground ducts B - Individual Wiring Enclosure

PVC Insulated - Current carrying capacity table single phase (in Amps)

Copper Conductor

Insulation PVC

Maximum Conductor Temperature 75⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu
1.0 16.0 16.0 13.0 13.0 11.0 6.0 18.0 21.0
1.5 21.0 21.0 16.0 18.0 14.0 8.0 23.0 26.0
2.5 30.0 29.0 23.0 24.0 20.0 12.0 32.0 36.0
4.0 40.0 39.0 31.0 32.0 25.0 16.0 41.0 47.0
6.0 51.0 49.0 40.0 41.0 33.0 20.0 52.0 58.0
10.0 69.0 67.0 54.0 54.0 44.0 27.0 69.0 77.0
16.0 92.0 89.0 72.0 70.0 56.0 36.0 89.0 99.0
25.0 124.0 119.0 97.0 94.0 75.0 48.0 116.0 129.0
35.0 153.0 145.0 119.0 112.0 90.0 59.0 139.0 155.0
50.0 187.0 177.0 146.0 138.0 110.0 0.0 168.0 186.0
70.0 238.0 223.0 184.0 170.0 136.0 0.0 206.0 228.0
95.0 295.0 276.0 230.0 212.0 169.0 0.0 252.0 278.0
120.0 344.0 321.0 267.0 242.0 193.0 0.0 287.0 316.0
150.0 395.0 367.0 308.0 282.0 225.0 0.0 329.0 354.0
185.0 459.0 424.0 358.0 320.0 256.0 0.0 373.0 408.0
240.0 549.0 505.0 428.0 381.0 305.0 0.0 438.0 472.0
300.0 636.0 582.0 495.0 0.0 0.0 0.0 496.0 546.0
400.0 744.0 676.0 577.0 0.0 0.0 0.0 575.0 621.0
500.0 867.0 780.0 668.0 0.0 0.0 0.0 649.0 721.0
630.0 1014.0 897.0 770.0 0.0 0.0 0.0 750.0 816.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Thermal insulation, partially surrounded by thermal insulation
Thermal Insulation, completely surrounded by thermal insulation
Underground ducts A - Undergound Wiring Enclosure
Underground ducts B - Individual Wiring Enclosure

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close