PVC Orange Circular 4C+E (450/750V & 0.6/1kV)

Products

1.5mm 4C&E O/C 0.6/1KV

Nexans ref. HNHP05AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 0 kN
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 71 mm
  • Minimum Bend Radius - Installed: 48 mm

 

1.5mm 4C&E O/C 0.6/1KV 500m

Nexans ref. HNHP05A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 0 kN
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 70 mm
  • Minimum Bend Radius - Installed: 48 mm

 

1.5mm 4C&E O/C 450/750V 100m

Nexans ref. GNHP05A1004OMAA

  • Packaging: Spool (100m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 0 kN
  • Maximum Pulling Tension: 1.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 60 mm
  • Minimum Bend Radius - Installed: 40 mm

 

1.5mm 4C&E O/C 450/750V 500m

Nexans ref. GNHP05A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 0 kN
  • Maximum Pulling Tension: 1.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 60 mm
  • Minimum Bend Radius - Installed: 40 mm

 

10mm 4C&E O/C 0.6/1KV

Nexans ref. HNHP13AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 10 mm²
  • Earth conductor cross section: 4 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 3 kN
  • Maximum Pulling Tension: 2.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 120 mm
  • Minimum Bend Radius - Installed: 77 mm

 

10mm 4C&E O/C 0.6/1KV 100m

Nexans ref. HNHP13A1004OMAA

  • Packaging: Spool (100m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 10 mm²
  • Earth conductor cross section: 4 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 3 kN
  • Maximum Pulling Tension: 2.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 120 mm
  • Minimum Bend Radius - Installed: 77 mm

 

10mm 4C&E O/C 0.6/1KV 500m

Nexans ref. HNHP13A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 10 mm²
  • Earth conductor cross section: 4 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 3 kN
  • Maximum Pulling Tension: 2.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 120 mm
  • Minimum Bend Radius - Installed: 77 mm

 

120mm 4C&E O/C 0.6/1KV

Nexans ref. HNHP23AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 120 mm²
  • Earth conductor cross section: 35 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 25 kN
  • Maximum Pulling Tension: 5.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 290 mm
  • Minimum Bend Radius - Installed: 190 mm

 

16mm 4C&E O/C 0.6/1KV

Nexans ref. HNHP15AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 4 kN
  • Maximum Pulling Tension: 2.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 130 mm
  • Minimum Bend Radius - Installed: 86 mm

 

16mm 4C&E O/C 0.6/1KV 100m

Nexans ref. HNHP15A1004OMAA

  • Packaging: Spool (100m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 4 kN
  • Maximum Pulling Tension: 2.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 130 mm
  • Minimum Bend Radius - Installed: 86 mm

 

16mm 4C&E O/C 0.6/1KV 500m

Nexans ref. HNHP15A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 4 kN
  • Maximum Pulling Tension: 2.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 130 mm
  • Minimum Bend Radius - Installed: 86 mm

 

2.5mm 4C&E O/C (450/750V)

Nexans ref. GNHP07AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 72 mm
  • Minimum Bend Radius - Installed: 48 mm

 

2.5mm 4C&E O/C (450/750V) 500m

Nexans ref. GNHP07A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 72 mm
  • Minimum Bend Radius - Installed: 48 mm

 

2.5mm 4C&E O/C (450/750v) 100m

Nexans ref. GNHP07A1004OMAA

  • Packaging: Spool (100m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 72 mm
  • Minimum Bend Radius - Installed: 48 mm

 

2.5mm 4C&E O/C 0.6/1KV

Nexans ref. HNHP07AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 80 mm
  • Minimum Bend Radius - Installed: 53 mm

 

2.5mm 4C&E O/C 0.6/1KV 500m

Nexans ref. HNHP07A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 80 mm
  • Minimum Bend Radius - Installed: 53 mm

 

25mm 4C&E O/C 0.6/1KV

Nexans ref. HNHC17AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 25 mm²
  • Earth conductor cross section: 6 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 7 kN
  • Maximum Pulling Tension: 2.9 kN
  • Minimum Bend Radius - During Installation (under Tension): 290 mm
  • Minimum Bend Radius - Installed: 200 mm

 

35mm 4C&E O/C 0.6/1KV

Nexans ref. HNHC18AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 35 mm²
  • Earth conductor cross section: 10 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 10 kN
  • Maximum Pulling Tension: 3.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 330 mm
  • Minimum Bend Radius - Installed: 220 mm

 

4mm 4C&E O/C 0.6/1KV

Nexans ref. HNHP09AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 92 mm
  • Minimum Bend Radius - Installed: 61 mm

 

4mm 4C&E O/C 0.6/1KV 500m

Nexans ref. HNHP09A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 92 mm
  • Minimum Bend Radius - Installed: 61 mm

 

4mm 4C&E O/C 450/750V

Nexans ref. GNHP09AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 83 mm
  • Minimum Bend Radius - Installed: 55 mm

 

4mm 4C&E O/C 450/750V 100m

Nexans ref. GNHP09A1004OMAA

  • Packaging: Spool (100m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 83 mm
  • Minimum Bend Radius - Installed: 55 mm

 

4mm 4C&E O/C 450/750V 500m

Nexans ref. GNHP09A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 1 kN
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 83 mm
  • Minimum Bend Radius - Installed: 55 mm

 

6mm 4C&E O/C 0.6/1KV

Nexans ref. HNHP11AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 2 kN
  • Maximum Pulling Tension: 2 kN
  • Minimum Bend Radius - During Installation (under Tension): 99 mm
  • Minimum Bend Radius - Installed: 66 mm

 

6mm 4C&E O/C 0.6/1KV 500m

Nexans ref. HNHP11A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 2 kN
  • Maximum Pulling Tension: 2 kN
  • Minimum Bend Radius - During Installation (under Tension): 99 mm
  • Minimum Bend Radius - Installed: 66 mm

 

6mm 4C&E O/C 450/750V

Nexans ref. GNHP11AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 2 kN
  • Maximum Pulling Tension: 1.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 90 mm
  • Minimum Bend Radius - Installed: 60 mm

 

6mm 4C&E O/C 450/750V 100m

Nexans ref. GNHP11A1004OMAA

  • Packaging: Spool (100m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 2 kN
  • Maximum Pulling Tension: 1.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 90 mm
  • Minimum Bend Radius - Installed: 60 mm

 

6mm 4C&E O/C 450/750V 500m

Nexans ref. GNHP11A5004OMAA

  • Packaging: Spool (500m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Rated Voltage Uo/U (Um): 450/750 V
  • Maximum Pull Tension of Conductor: 2 kN
  • Maximum Pulling Tension: 1.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 90 mm
  • Minimum Bend Radius - Installed: 60 mm

 

70mm 4C&E O/C 0.6/1KV

Nexans ref. HNHC20AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 70 mm²
  • Earth conductor cross section: 25 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 20 kN
  • Maximum Pulling Tension: 4.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 430 mm
  • Minimum Bend Radius - Installed: 290 mm

 

95mm 4C&E O/C 0.6/1KV

Nexans ref. HNHC22AA004OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 95 mm²
  • Earth conductor cross section: 25 mm²
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Maximum Pull Tension of Conductor: 25 kN
  • Maximum Pulling Tension: 5 kN
  • Minimum Bend Radius - During Installation (under Tension): 500 mm
  • Minimum Bend Radius - Installed: 340 mm

 

Description

Description

Standards

  • National
    AS/NZS 1125; AS/NZS 5000.1; AS/NZS 5000.2
  • 4 core+earth, circular,
  • V-90 insulated,
  • 90°C PVC sheathed to AS/NZS 5000,
  • Copper conductors.
  • GNHP 450/750V to AS/NZS 5000.2
  • HNHP 0.6/1kV to AS/NZS 5000.1

Note: Earth cores smaller than 25mm² are not compacted.
* Due to a change in standard AS/NZS 5000.2, the minimum calculated value of the sheath thickness for circular multicore cables has reduced, therefore also reducing the OD and mass for 1.5mm2–6mm2 cables.

 

Orange Circular; Circs

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Orange
Conductor flexibility
Class 2
Conductor material
Copper
Conductor shape
Circular
Insulation
V-90
Outer sheath
PVC

Dimensional characteristics

Dimensional characteristics

Number of cores
4
Number of earth cores
1

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid

Resources

Resources

PVC Circular 3C + 4C and Earth - Current carrying capacities three phase (in Amps)

Copper Conductor

Insulation PVC

Maximum Conductor Temperature 75⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 13.0 12.0 9.0 6.0 11.0 9.0 5.0 19.0 14.0
1.5 16.0 15.0 12.0 8.0 14.0 11.0 7.0 24.0 18.0
2.5 23.0 22.0 17.0 11.0 20.0 16.0 10.0 34.0 25.0
4.0 31.0 29.0 23.0 15.0 25.0 20.0 13.0 44.0 33.0
6.0 40.0 37.0 30.0 19.0 33.0 26.0 16.0 55.0 42.0
10.0 54.0 51.0 41.0 25.0 44.0 35.0 22.0 74.0 55.0
16.0 72.0 68.0 54.0 34.0 58.0 47.0 29.0 96.0 73.0
25.0 97.0 91.0 73.0 46.0 76.0 60.0 38.0 125.0 94.0
35.0 120.0 112.0 90.0 56.0 94.0 75.0 47.0 150.0 114.0
50.0 146.0 137.0 109.0 0.0 112.0 89.0 0.0 178.0 136.0
70.0 185.0 172.0 138.0 0.0 142.0 114.0 0.0 219.0 170.0
95.0 228.0 213.0 170.0 0.0 177.0 142.0 0.0 263.0 208.0
120.0 265.0 247.0 198.0 0.0 202.0 162.0 0.0 300.0 237.0
150.0 303.0 282.0 226.0 0.0 228.0 182.0 0.0 336.0 266.0
185.0 348.0 324.0 259.0 0.0 263.0 211.0 0.0 379.0 304.0
240.0 412.0 383.0 307.0 0.0 316.0 253.0 0.0 438.0 359.0
300.0 472.0 438.0 0.0 0.0 0.0 0.0 0.0 493.0 404.0
400.0 544.0 504.0 0.0 0.0 0.0 0.0 0.0 557.0 468.0
500.0 616.0 571.0 0.0 0.0 0.0 0.0 0.0 620.0 522.0
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground ducts

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close