Alsecure® PLUS Single Core

Products

ALSECURE@ PLUS 1CX10 GMTXLPHFS TP 110°C

Nexans ref. PFLX01AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 10 mm²
  • Nominal overall diameter: 8.9 mm

ALSECURE@ PLUS 1CX35 GMTXLPHFS TP 110°C

Nexans ref. PFLX04AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Nominal overall diameter: 13.5 mm

ALSECURE@ PLUS 1CX50 GMTXLPHFS TP 110°C

Nexans ref. PFLX05AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Nominal overall diameter: 15.3 mm

ALSECURE@ PLUS 1CX630 GMTXLPHFS TP 110°C

Nexans ref. PFLE94AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Nominal overall diameter: 45.0 mm

CU ALSEC RHE-1 FLEX 1x 16 110

Nexans ref. PFLX02AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Nominal overall diameter: 10.1 mm

CU ALSEC RHE-1 FLEX 1x 25 110

Nexans ref. PFLX03AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Nominal overall diameter: 11.6 mm

CU ALSEC RHE-1 FLEX 1x 70 110

Nexans ref. PFLX06AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Nominal overall diameter: 17.2 mm

CU ALSEC RHE-1 FLEX 1x 95 110

Nexans ref. PFLX07AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Nominal overall diameter: 19.3 mm

CU ALSEC RHE-1 FLEX 1x120 110

Nexans ref. PFLE87AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Nominal overall diameter: 21.6 mm

CU ALSEC RHE-1 FLEX 1x150 110

Nexans ref. PFLE88AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Nominal overall diameter: 23.5 mm

CU ALSEC RHE-1 FLEX 1x185 110

Nexans ref. PFLE89AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal overall diameter: 26.2 mm

CU ALSEC RHE-1 FLEX 1x240 110

Nexans ref. PFLE90AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal overall diameter: 29.1 mm

CU ALSEC RHE-1 FLEX 1x300 110

Nexans ref. PFLE91AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Nominal overall diameter: 31.8 mm

CU ALSEC RHE-1 FLEX 1x400 110

Nexans ref. PFLE92AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Nominal overall diameter: 35.9 mm

CU ALSEC RHE-1 FLEX 1x500 110

Nexans ref. PFLE93AA001JBNA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 500 mm²
  • Nominal overall diameter: 40.8 mm

Description

Description

Standards

  • National
    AS/NZS 3013; AS/NZS 5000.1

Construction Stranded Flexible (Class 5) Plain Annealed Copper Conductor, Mica Taped,
X-HF-110 Insulated, HFS-110-TP Sheathed to AS/NZS 5000.1, 110°C, WS52W Fire Rated to AS/NZS 3013.

Alsecure® Plus Single Core  cables are a range of Fire Rated single core products for use in mains and sub-mains applications.

Rated to 0.6/1kV, 110°C, this LSOH range of Fire Rated cables will maintain circuit integrity and life-saving essential services in the event of fire.

The Alsecure® Plus Single Core range is available in sizes from 10mm² to 630mm².

Features

  • Flexible stranded copper conductor
  • Halogen free, low smoke, low toxic and corrosive emissions, & flame retardant materials
  • 110ºC rated insulation and sheath
  • WS52W Rated to AS/NZS 3013

Benefits

  • Flexibility for fast, easy installation
  • Contributes to the green star rating of your project
  • Safer evacuation and better protection for essential building systems

The Alsecure Plus product range is suitable for Green Star Buildings as they do not contain any PVC.

Applications

  • Fire resistant Power Circuit
  • Consumer mains and Subs Mains
  • Lift sub mains
  • Power Cable to fire pumps
  • Power Cable for essential circuit

Voltage
0.6 / 1 KV

Continuous Operating Temperature
110°C

Colours
Insulation - White(Natural)
Outer Sheath - RED Only

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Red
Conductor material
Annealed copper
Insulation
X-HF-110
Outer sheath
HFS-110-TP
Type of conductor
Stranded flexible

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/1 kV

Usage characteristics

Usage characteristics

Maximum operating temperature
110 °C

Resources

Resources

Alsecure Plus single core - Current carrying capacity table single phase (in Amps)

Flexible Copper Conductor

Insulation XLPE-110

Maximum Conductor Temperature 110⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 26.0 26.0 21.0 21.0 16.0 10.0 33.0 24.0 27.0
1.5 32.0 32.0 26.0 25.0 20.0 13.0 40.0 30.0 34.0
2.5 43.0 42.0 34.0 33.0 27.0 17.0 53.0 39.0 44.0
4.0 57.0 56.0 45.0 45.0 36.0 23.0 69.0 51.0 57.0
6.0 73.0 70.0 57.0 56.0 45.0 29.0 86.0 64.0 71.0
10.0 102.0 98.0 80.0 77.0 61.0 40.0 117.0 86.0 96.0
16.0 135.0 129.0 105.0 102.0 82.0 53.0 151.0 112.0 125.0
25.0 178.0 170.0 139.0 133.0 106.0 70.0 192.0 143.0 158.0
35.0 221.0 210.0 172.0 167.0 133.0 86.0 232.0 176.0 195.0
50.0 279.0 263.0 218.0 207.0 165.0 0.0 284.0 215.0 237.0
70.0 351.0 329.0 273.0 263.0 210.0 0.0 345.0 266.0 287.0
95.0 422.0 395.0 329.0 312.0 250.0 0.0 403.0 312.0 341.0
120.0 500.0 466.0 390.0 364.0 291.0 0.0 464.0 359.0 392.0
150.0 577.0 536.0 450.0 426.0 341.0 0.0 524.0 414.0 451.0
185.0 660.0 611.0 516.0 481.0 385.0 0.0 585.0 464.0 503.0
240.0 794.0 732.0 621.0 583.0 467.0 0.0 682.0 548.0 599.0
300.0 916.0 841.0 716.0 0.0 0.0 0.0 769.0 631.0 675.0
400.0 1105.0 1006.0 860.0 0.0 0.0 0.0 893.0 734.0 784.0
500.0 1290.0 1164.0 999.0 0.0 0.0 0.0 1009.0 855.0 909.0
630.0 1529.0 1359.0 1168.0 0.0 0.0 0.0 1154.0 977.0 1046.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual wiring enclosure

Alsecure Plus single core - Current carrying capacity table three phase (in Amps)

Flexible Copper Conductor

Insulation XLPE-110

Maximum Conductor Temperature 110⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 25.0 22.0 21.0 18.0 15.0 10.0 28.0 21.0 25.0
1.5 31.0 27.0 26.0 23.0 19.0 13.0 35.0 26.0 31.0
2.5 42.0 36.0 34.0 31.0 24.0 17.0 46.0 34.0 40.0
4.0 55.0 48.0 45.0 40.0 32.0 23.0 59.0 44.0 52.0
6.0 70.0 61.0 57.0 50.0 40.0 29.0 74.0 55.0 65.0
10.0 99.0 85.0 80.0 70.0 56.0 40.0 99.0 76.0 87.0
16.0 130.0 112.0 105.0 91.0 73.0 53.0 127.0 97.0 113.0
25.0 173.0 149.0 139.0 121.0 97.0 70.0 162.0 125.0 143.0
35.0 214.0 184.0 172.0 148.0 118.0 86.0 196.0 151.0 176.0
50.0 270.0 233.0 217.0 190.0 152.0 0.0 238.0 188.0 213.0
70.0 340.0 292.0 273.0 234.0 187.0 0.0 290.0 229.0 257.0
95.0 410.0 353.0 329.0 277.0 221.0 0.0 338.0 268.0 306.0
120.0 487.0 418.0 390.0 331.0 265.0 0.0 388.0 316.0 350.0
150.0 562.0 482.0 450.0 378.0 302.0 0.0 438.0 357.0 403.0
185.0 644.0 553.0 516.0 438.0 350.0 0.0 489.0 404.0 448.0
240.0 775.0 665.0 620.0 538.0 430.0 0.0 569.0 481.0 534.0
300.0 895.0 766.0 714.0 612.0 489.0 0.0 641.0 542.0 600.0
400.0 1079.0 918.0 855.0 757.0 606.0 0.0 742.0 648.0 693.0
500.0 1260.0 1064.0 990.0 864.0 691.0 0.0 835.0 729.0 803.0
630.0 1493.0 1240.0 1154.0 993.0 794.0 0.0 950.0 828.0 918.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual wiring enclosure

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close