Covered Conductors Type (CCT)

Products

19/3.5mm CCT Grey NEW

Nexans ref. UJAJ73AA001AAGX

  • Packaging: Cut to length (1000m)
  • Conductor cross-section: 180 mm²

19/3.5mm CCT Grey

Nexans ref. UJAJ73SC001AAGX

  • Conductor cross-section: 180 mm²

3/7.35mm CCT Grey

Nexans ref. UJAJ87SC001AAGX

  • Conductor cross-section: 80 mm²

7/2.75mm CCT Grey

Nexans ref. UJAJ12A2501AAGX

  • Packaging: Pack (250m)
  • Conductor cross-section: 40 mm²

7/4.75mm CCT Grey NEW

Nexans ref. UJAJ90A2501AAGX

  • Packaging: Pack (250m)
  • Conductor cross-section: 120 mm²

7/4.75mm CCT Grey

Nexans ref. UJAJ90SC001AAGX

  • Conductor cross-section: 120 mm²

AL AERIAL CCT MV11 7/3.75 XL NEW

Nexans ref. UJAJ87AA001AAGX

  • Packaging: Cut to length (1100m)
  • Conductor cross-section: 80 mm²

CCT 12.7/22kV

Nexans ref. ULAJ87AA001

  • Conductor cross-section: 80 mm²

CCT 12.7/22kV

Nexans ref. ULAJ90AA001

  • Conductor cross-section: 120 mm²

CCT 12.7/22kV

Nexans ref. ULAJ73AA001

  • Conductor cross-section: 180 mm²

CCT 19/33kV

Nexans ref. UNAJ87AA001

  • Conductor cross-section: 80 mm²

CCT 19/33kV

Nexans ref. UNAJ90AA001

  • Conductor cross-section: 120 mm²

CCT 19/33kV

Nexans ref. UNAJ73AA001

  • Conductor cross-section: 180 mm²

CCT 6.35/11kV

Nexans ref. UJAJ12AA001

  • Conductor cross-section: 40 mm²

CCT 6.35/11kV

Nexans ref. UJAJ87AA001

  • Conductor cross-section: 80 mm²

CCT 6.35/11kV

Nexans ref. UJAJ73AA001

  • Conductor cross-section: 180 mm²

CCT 6.35/11kV

Nexans ref. UJAJ83AA001

  • Conductor cross-section: 240 mm²

Description

Description

CCT covered conductors have a specified thickness of covering for each of the nominated working voltages. While still required to operate under similar principles to a bare wire or CC system, they have electrical and mechanical characteristics which permit them to remain in contact with tree limbs for an extended period dependent on abrasive characteristics of the tree, frequency and strength of prevailing winds and operating temperature. CCT show better performance in polluted environments. They are suitable for use in 'spacer cable' systems and in the insulated unscreened conductor (IUC) systems.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
aluminum alloy
Covering
XLPE

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close