XLPE/PVC 2C+E & 3C+E 0.6/1kV Circular

Products

2X16mm2 + E XLPE/PVC Circular Orange

Nexans ref. DTHP15AA002OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 2
  • Maximum Pull Tension of Conductor: 2 kN
  • Maximum Pulling Tension: 2.1 kN
  • Minimum Bend Radius - During Installation (under Tension): 100 mm
  • Minimum Bend Radius - Installed: 68 mm

 

2X25mm2 + E XLPE/PVC Circular Orange

Nexans ref. DTHC17AA002OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 25 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 2
  • Maximum Pull Tension of Conductor: 4 kN
  • Maximum Pulling Tension: 2.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 230 mm
  • Minimum Bend Radius - Installed: 150 mm

 

2X35mm2 + E XLPE/PVC Circular Orange

Nexans ref. DTHC18AA002OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 35 mm²
  • Earth conductor cross section: 10 mm²
  • Number of cores: 2
  • Maximum Pull Tension of Conductor: 5 kN
  • Maximum Pulling Tension: 2.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 260 mm
  • Minimum Bend Radius - Installed: 170 mm

 

3X120mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHP23AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 120 mm²
  • Earth conductor cross section: 35 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 25 kN
  • Maximum Pulling Tension: 4.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 360 mm
  • Minimum Bend Radius - Installed: 240 mm

 

3X150mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHP24AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 150 mm²
  • Earth conductor cross section: 50 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 25 kN
  • Maximum Pulling Tension: 5.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 400 mm
  • Minimum Bend Radius - Installed: 270 mm

 

3X16mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHP15AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 3 kN
  • Maximum Pulling Tension: 2.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 110 mm
  • Minimum Bend Radius - Installed: 74 mm

 

3X185mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHP25AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 185 mm²
  • Earth conductor cross section: 70 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 25 kN
  • Maximum Pulling Tension: 6 kN
  • Minimum Bend Radius - During Installation (under Tension): 450 mm
  • Minimum Bend Radius - Installed: 300 mm

 

3X25mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHC17AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 25 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 5 kN
  • Maximum Pulling Tension: 2.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 250 mm
  • Minimum Bend Radius - Installed: 170 mm

 

3X35mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHC18AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 35 mm²
  • Earth conductor cross section: 10 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 7 kN
  • Maximum Pulling Tension: 2.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 280 mm
  • Minimum Bend Radius - Installed: 190 mm

 

3X50mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHC19AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 50 mm²
  • Earth conductor cross section: 16 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 10 kN
  • Maximum Pulling Tension: 3.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 320 mm
  • Minimum Bend Radius - Installed: 210 mm

 

3X70mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHC20AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 70 mm²
  • Earth conductor cross section: 25 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 15 kN
  • Maximum Pulling Tension: 3.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 370 mm
  • Minimum Bend Radius - Installed: 240 mm

 

3X95mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHC22AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Compact copper
  • Conductor cross-section: 95 mm²
  • Earth conductor cross section: 25 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 20 kN
  • Maximum Pulling Tension: 4.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 420 mm
  • Minimum Bend Radius - Installed: 280 mm

 

3x240mm2 + E XLPE/PVC Circular Orange

Nexans ref. FTHP26AA003OMAA

  • Packaging: Cut to length (m)
  • Type of conductor: Stranded copper
  • Conductor cross-section: 240 mm²
  • Earth conductor cross section: 95 mm²
  • Number of cores: 3
  • Maximum Pull Tension of Conductor: 25 kN
  • Maximum Pulling Tension: 6.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 510 mm
  • Minimum Bend Radius - Installed: 340 mm

 

Description

Description

Standards

  • National
    AS/NZS 1125; AS/NZS 5000.1
  • 2 & 3 core+earth, circular,
  • 0.6/1kV X-90 insulated,
  • PVC sheathed to AS/NZS 5000.1
  • Copper conductors, 90°C.

Note: Earth cores smaller than 25mm2 are not compacted. 

 

Orange Circular; Circs

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Orange
Conductor flexibility
Class 2
Conductor material
Copper
Conductor shape
Circular
Insulation
X-90
Outer sheath
PVC
With Green/Yellow core
Yes

Dimensional characteristics

Dimensional characteristics

Number of earth cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Resources

Resources

XLPE/PVC Circular (2 Core+E) - Current carrying capacities single phase (in Amps)

Insulation type: X-90, X-HF-90, R-EP-90, R-CPE-90, R-HF-90 OR R-CSP-90

Maximum conductor temperature: 90°C

Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 18.0 17.0 14.0 9.0 16.0 12.0 8.0 26.0 19.0
1.5 24.0 22.0 18.0 11.0 20.0 16.0 10.0 33.0 24.0
2.5 34.0 31.0 25.0 16.0 28.0 23.0 14.0 46.0 34.0
4.0 45.0 42.0 33.0 21.0 37.0 29.0 18.0 60.0 45.0
6.0 57.0 53.0 42.0 27.0 46.0 37.0 23.0 75.0 56.0
10.0 78.0 73.0 58.0 36.0 63.0 51.0 32.0 101.0 75.0
16.0 104.0 97.0 78.0 49.0 82.0 66.0 41.0 132.0 98.0
25.0 140.0 131.0 105.0 66.0 110.0 88.0 55.0 170.0 128.0
35.0 173.0 162.0 129.0 81.0 132.0 106.0 66.0 205.0 154.0
50.0 211.0 197.0 158.0 0.0 162.0 130.0 0.0 244.0 185.0
70.0 268.0 250.0 200.0 0.0 200.0 160.0 0.0 300.0 228.0
95.0 331.0 309.0 247.0 0.0 250.0 200.0 0.0 360.0 279.0
120.0 385.0 359.0 287.0 0.0 285.0 228.0 0.0 410.0 318.0
150.0 441.0 411.0 328.0 0.0 332.0 265.0 0.0 460.0 365.0
185.0 509.0 473.0 379.0 0.0 377.0 301.0 0.0 520.0 413.0
240.0 604.0 562.0 449.0 0.0 448.0 358.0 0.0 603.0 485.0
300.0 694.0 645.0 516.0 0.0 523.0 418.0 0.0 680.0 558.0
400.0 804.0 745.0 596.0 0.0 596.0 477.0 0.0 771.0 633.0
500.0 915.0 848.0 678.0 0.0 695.0 556.0 0.0 862.0 728.0
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure

XLPE/PVC Circular 3C+E and 4C+E - Current carrying capacities three phase (in Amps)

Insulation type: X-90, X-HF-90, R-EP-90, R-CPE-90, R-HF-90 OR R-CSP-90

Maximum conductor temperature: 90°C

Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 16.0 14.0 12.0 7.0 13.0 10.0 6.0 22.0 16.0
1.5 20.0 19.0 15.0 9.0 16.0 13.0 8.0 28.0 20.0
2.5 28.0 26.0 21.0 13.0 24.0 19.0 12.0 39.0 29.0
4.0 38.0 35.0 28.0 18.0 30.0 24.0 15.0 51.0 37.0
6.0 48.0 45.0 36.0 22.0 38.0 30.0 19.0 63.0 46.0
10.0 66.0 62.0 49.0 31.0 53.0 42.0 26.0 85.0 63.0
16.0 88.0 83.0 66.0 41.0 68.0 55.0 34.0 110.0 81.0
25.0 119.0 111.0 89.0 56.0 91.0 73.0 46.0 143.0 107.0
35.0 147.0 137.0 110.0 69.0 114.0 91.0 57.0 172.0 130.0
50.0 180.0 168.0 134.0 0.0 136.0 108.0 0.0 204.0 155.0
70.0 229.0 213.0 170.0 0.0 173.0 138.0 0.0 251.0 193.0
95.0 283.0 263.0 210.0 0.0 209.0 167.0 0.0 302.0 233.0
120.0 330.0 306.0 245.0 0.0 246.0 197.0 0.0 344.0 270.0
150.0 377.0 350.0 280.0 0.0 277.0 222.0 0.0 385.0 304.0
185.0 436.0 404.0 323.0 0.0 322.0 257.0 0.0 435.0 348.0
240.0 517.0 479.0 383.0 0.0 386.0 309.0 0.0 504.0 411.0
300.0 594.0 549.0 0.0 0.0 0.0 0.0 0.0 567.0 463.0
400.0 685.0 632.0 0.0 0.0 0.0 0.0 0.0 640.0 524.0
500.0 779.0 718.0 0.0 0.0 0.0 0.0 0.0 714.0 601.0
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close